EPC-3D-Diff: Equivariant Physics Consistent Conditional 3D Latent Diffusion for CBCT to CT Synthesis
cs.CV, cs.AI, physics.med-ph
Submitted: 2026-05-19
Updated: 2026-09-08
Comments: 10 pages, 4 figures
Journal ref: Medical Image AI in Radiation Therapy (MIART), MICCAI 2026
Code: https://github.com/ALZAHRAALTALIB/EPC-3D-Diff
License: http://creativecommons.org/licenses/by/4.0/
The gist: Cone-beam CT (CBCT) is routinely acquired during radiotherapy for patient setup, but its quantitative reliability is degraded by scatter, noise, and reconstruction artifacts, limiting Hounsfield Unit
Terminology
Abstract
Cone-beam CT (CBCT) is routinely acquired during radiotherapy for patient setup, but its quantitative reliability is degraded by scatter, noise, and reconstruction artifacts, limiting Hounsfield Unit (HU) accuracy. We propose EPC-3D-Diff, a novel conditional 3D latent diffusion framework for volumetric CBCT to CT synthesis that introduces a projection domain equivariance loss derived from acquisition physics. Unlike common image domain equivariance, we exploit the fact that an in plane rotation of the volume corresponds to an angular shift in its projections. During training, we enforce this relationship by forward projecting rotated synthesized CT volumes and matching them to appropriately angle shifted projections of the paired target CT, yielding a physics consistent equivariance constraint integrated into the diffusion objective. To capture full 3D context efficiently, conditional diffusion is performed in a compact latent space learnt by a lightweight 3D autoencoder, preserving axial depth while downsampling in plane resolution for stable training. We validate on a paired head CBCT/CT phantom dataset, including repeat scans, and paired clinical data using patient wise splits, and perform single and mixed domain training, ablations, and comparisons with diffusion and CycleGAN. EPC-3D-Diff generalizes well and achieved substantial improvements, +7.4 dB (phantom) and +1.8 dB (clinical data) in PSNR compared to state of the art methods, alongside improved SSIM and HU accuracy, within tissue boundaries. Overall, EPC-3D-Diff improves robustness and physics consistency, supporting HU aware synthesis for downstream radiotherapy workflows. The open source code for EPC-3D-Diff is available at https://github.com/ALZAHRAALTALIB/EPC-3D-Diff.
Sources
Related papers
- Loss Knows Best: Detecting Annotation Errors in Videos via Loss Trajectories
- AnchorWeave: World-Consistent Video Generation with Retrieved Local Spatial Memories
- Benchmarking the Robustness of Foundation Models for Mammography under Domain Shift
- MambaX-Net: Dual-Input Mamba-Enhanced Cross-Attention Network for Longitudinal MRI Segmentation
- TeleOCR: Navigating Document Parsing Across Digital and Camera-Captured Documents
- A Survey on Efficient Vision-Language-Action Models